Alfa Laval Clip 3
CLIP3-RM 126PL 4SEC
- Superior hygienic safety – plates designed for food applications
- Gentle treatment of sensitive products
- Uncompromising cleanliness
- Flexible configuration – possible to rebuild the heat exchanger
About
Alfa Laval ClipLine is a premium range of heat exchangers for smaller duties in dairy, food, beverage and other hygienic applications requiring gentle product treatment, long operating times or superior cleanability.
The Clip plate has a chevron type of plate pattern designed for hygienic conditions. The entry points, the distribution area and the shape and pressing depth of the plate pattern give optimal performance.
Documentation
Technical details
Heat recovery
94%Flow rate primary side (kg/h)
1000 kg/hTemp primary side (°C)
4 → 74 → 4 °CPressure drop primarySide (kPa)
297 kPaCooling media
Ice waterFlow rate cooling (kg/h)
1223 kg/hTempCooling (°C)
2 °CPressure drop cooling (kPa)
20 kPaHeating media
Hot waterFlow rate heating (kg/h)
905 kg/hTempHeating (°C)
75 °CPressure drop heating (kPa)
38 kPaMin. CIP flow rate (kg/h)
800 kg/hPressure dropCIP (kPa)
187 kPa